TECHNOLOGY | |
Topology | Symmetric triaxial |
Feedback | Force balance with capacitive transducer |
Levelling | Automatic motorized mechanical |
Alignment | Vertical scribe marks for (N and S); Precision guide in cover for straight-edge, line or laser level; Holes for 5/16" alignment (E and W) |
PERFORMANCE | |
Self-noise | Below the NLNM at 100 seconds |
Sensitivity | 1200 V-s/m ±0.5% precision, Contact factory for other options |
Bandwidth | -3 dB points at 120s and 145 Hz |
Clip Level | > 16.6 mm/s up to 10 Hz and 0.17g above 10 Hz |
Temperature | ±45°C without re-centering |
INTERFACE | |
Connector | 20-pin marine |
Velocity Output | 40 V peak-to-peak differential; Selectable XYZ or UVW mode |
Mass Position Output | Three independent voltage outputs |
Calibration Input | Single voltage input for all channels
Calibration in XYZ or UVW |
Serial Port | For enhanced instrument control and status:
Mass center, UVW/XYZ mode, short/long period mode, firmware updates Temperature, mass position, instrument status, serial number |
POWER | |
Supply Voltage | 9 to 36 volts DC isolated input |
Power Consumption | 560 mW typical at 15 V input |
Protection | Reverse-voltage protection; Auto-resettable over-current protection
(No fuse to replace) |
PHYSICAL | |
Diameter | 143 mm |
Height | 430 mm, not including connector |
Weight | 16 Kg |
Handling | Detachable carrying handle on lid |
ENVIRONMENTAL | |
Operating temp | -40°C to +55°C |
Humidity | 0 to 100% |
Shock | 20g half sine, 5 ms without damage, 6 axis;
No mass lock required for transport |
Rugged | Rated to IP68 and NEMA6P for outdoor use |
Specifications subject to change without notice