The Trillium Compact Exploration has been designed for rapid and repeated deployments and is specifically tuned for frequencies of 1Hz to 10Hz. It features an ultra-low noise floor and 20s corner frequency. Areas of application include:
TECHNOLOGY | |
Topology | Symmetric tri-axial |
Feedback | Force balance with capacitive transducer |
Mass Centering | Not required |
Levelling | No levelling within 10° vertical |
Alignment | Vertical scribe marks for N/S
Precision N/S-E/W guide in top of cover for straight-edge, line, or laser level |
PERFORMANCE | |
Self-noise | See Performance |
Sensitivity | 750 V-s/m nominal ± 1% precision |
Off-axis Sensitivity | ± 0.5% |
Bandwidth | -3db points at 20s and 100 Hz |
Transfer Function | Lower corner poles within ±1% of nominal provided
High-frequency poles within ±5% of nominal provided No peak in response at high frequency |
Clip Level | 26 mm/s from 0.1 Hz to 10 Hz |
Operational Tilt Range | ±10° |
Parasitic Resonances | None below 200 Hz |
INTERFACE | |
Connector | 14-pin, shell size 12, MIL-C-26482 Series I, top mounted |
Velocity Output | 2.5 or 5 V peak-to-peak differential |
Mass Position | Selectable XYZ or UVW mode |
Output | Single voltage output representing maximum mass position |
Calibration Input | Single voltage input and one active high control signal to enable all 3 channels.
Remote calibration in XYZ or UVW mode Independent channel selection by serial port |
DIGITAL COMMAND AND CONTROL INTERFACE | |
Digital Interface | RS-232 compatible serial IP (SLIP)
Onboard web server standard HTTP |
Digital Commands | XYZ, UVW mode switching
Calibration channel selection (off, enable all, u, v, or w) Short/long period mode Firmware updates State-of-health request |
Digital Data Outputs | Independent mass position values
Instrument temperature Factory sensitivity Instrument serial number and firmware revision |
POWER | |
Supply Voltage | 9-36 V DC isolated input |
Power Consumption | 165 mW typical when level
Up to 250 mW when tilted |
Protection | Reverse-voltage and over-voltage protected
Self-resetting over-current protection |
Specifications subject to change without notice